Wohler AMP2-DA User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
© 2002 Wohler Technologies Inc. ALL rights reserved
AMP2-DA Instruction and Service Manual P/N 821505 Rev-B Section 2: Operation
Front Panel Features
10
11
AES Source Select Switch
This two position toggle switch allows the operator to select either one of the two AES/EBU IN inputs (IN 1 or IN 2) on the
rear panel (Item C, page 14) as sources for monitoring. It should be noted that in order for the unit to monitor the selected
AES source, the ANALOG/DIGITAL Source Select Switch (Item 6, page 10) must be set to DIGITAL.
AES Signal Error Indication LED
This bi-color (GREEN/RED) LED indicates the input status of the AES input signal selected by the AES Source Select
Switch (1 or 2) (Item 10). This LED functions regardless of the position of the ANALOG/DIGITAL Source Select
Switch (Item 6, page 10).
The LED glows GREEN as long as a valid AES/EBU digital datastream for the associated input channel is being received. The
LED glows RED to indicate errors in reception or data errors (if the data has been tagged as inappropriate for conversion to
analog by having the validity bit set).
An optional feature of the AES signal error detection is the ability to mute the audio when errors are detected in the AES
signal. To enable this feature, a jumper is placed at H12 of the 919117 PCB. See page 30 for location of H12 on the 919117
PCB.
(Continued)
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 25 26

Comments to this Manuals

No comments