10
Chapter 2 Audio and Metering
Configuration Options
Configuration Options
The AMP1-16 Series monitors are very flexible and can be configured to
adapt to almost any audio configuration. The available adjustments are:
Selecting the inputs (signal sources) to monitor
Trimming the volume of each channel
Indicating the phase relationship of each channel pair
Muting the audio output of the speakers
Selecting the signal sources for the AES and analog rear panel
outputs
Selecting the Monitor Downmix
Setting the audio delay for video synchronization
Configuring the Audio Outputs
Overview
You can route the digital audio signals at the inputs of the AMP1-16-3G
Series monitors to the front panel speakers or to the outputs, depending
on your needs. The internal routing paths are controlled by the settings
in the setup menus. The following diagram (Figure 2–1) shows the
relationship between the internal routing paths and the various menus
that control the signal flow.
The colors in this diagram represent various audio formats or levels of
processing. Each menu will select, route, or adjust the audio paths.
Further detail on each of these menus is available in Chapter 5: Menu
List on page 39.
Note that you can set up multiple audio paths. For example, while
monitoring de-embedded SDI audio channels through the speakers,
you may independently decode Dolby channels from an AES stream,
convert them to analog, and output them. Setups like this can be stored