821030: AMPx-S8 Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
20
Chapter 2 System Overview
Monitoring Inputs
Monitoring Inputs
System Overview
The following simple instructions will allow you to get your AMPx-S8
Series monitor up and running quickly; that is, you will be able to
monitor any single input through the monitor’s internal speakers.
Referring to the AMPx-S8 Series rear panel diagrams (Figure 2–5 and 2–
6 on page 14) and the front panel controls (Figure 2–1 and 2–2 on page
9) follow the instructions below by signal/connector type.
Monitoring an Analog Input
1. To monitor an analog signal, connect the analog input to the rear
panel Balanced Analog In (DB-25) connector.
2. On the front panel, press the Input button until the LCD screen
displays Analog.
6 Custom Settings for Alternate Scales
7Not Used
8
For software Upgrades Only
9
Table 2–7 Reference Setting Values and Definitions
Position
Reference Level Function
Analog (dBu) Digital (dBFS)
Example: Choosing position 2 (0 dBu = -20 dBFS) means an analog input level of
0 dBu will light up the LED segment associated with the digital -20
dBFS value on the bar graph meter and also transition from green to
amber at that segment.
Note:
For a complete description of each front panel control, refer
to Front Panel Controls on page 8.
For a complete description of each rear panel connector,
refer to Rear Panel Connectors on page 13.